Begin Part Validation | Manhole No. 5 (pipe to 42in) (MH-1.3) Begin Part Family self validation test Part Family self-validation complete, no errors found OK: Part Domain parameter validated -- Structure_Domain ERROR: Part Type parameter not validated OK: Part Subtype parameter validated -- Eccentric OK: Part Description parameter validated -- Manhole No. 5 (pipe to 42in) (MH-1.3) OK: Part Name parameter validated -- Manhole No. 5 (pipe to 42in) (MH-1.3) OK: Part Size Name parameter found OK: Unique Part ID validated -- A095735B-7AD9-4118-8013-9591EAA0994A OK: Data Version parameter validated, version = 2.0 OK: Sample Expanded Table row successfully created ERROR: Duplicate Parameter Name: PipeDiam ERROR: Duplicate Parameter Desc: Outlet Pipe Diameter ERROR: Duplicate Parameter Name: PTh ERROR: Duplicate Parameter Desc: Outlet Pipe Thickness Begin Calc Usage Validation OK: Calc Parameter PrtSN uses Context=Catalog_PartSizeName OK: Calc Parameter STest2 uses Context=PartSizeValidation_Test OK: Calc Parameter STest1 uses Context=PartSizeValidation_Test OK: Calc Parameter DPTh uses Context=DropPipeThickness OK: Calc Parameter PTh uses Context=OutletPipeThickness OK: Calc Parameter BdyD1 uses Context=BodyGeometry_Diameter OK: Calc Parameter BdyD4 uses Context=BodyGeometry_Diameter OK: Calc Parameter BdyD5 uses Context=BodyGeometry_Diameter OK: Calc Parameter BdyD7 uses Context=BodyGeometry_Diameter OK: Calc Parameter FTh uses Context=FloorThickness OK: Calc Parameter LenA4 uses Context=Geometry_Distance2D OK: Calc Parameter LenA5 uses Context=Geometry_Distance2D OK: Calc Parameter LenA6 uses Context=Geometry_Distance2D OK: Calc Parameter PTh uses Context=Geometry_ModelDistanceParameter OK: Calc Parameter SBSD uses Context=StructDiameter OK: Calc Parameter SBSH uses Context=StructHeight OK: Calc Parameter SID uses Context=StructInnerDiameter OK: Calc Parameter SVPC uses Context=StructVertPipeClearance OK: Calc Parameter WPOf1 uses Context=Geometry_WorkplaneOffset OK: Calc Parameter WPOf3 uses Context=Geometry_WorkplaneOffset OK: Calc Parameter WPOf4 uses Context=Geometry_WorkplaneOffset OK: Calc Parameter WPOf5 uses Context=Geometry_WorkplaneOffset OK: Calc Parameter WTh uses Context=WallThickness OK: Calc Parameter LenA3 uses Context=Geometry_Distance2D ERROR: Table Data Validation Failed | C:\ProgramData\Autodesk\C3D 2014\enu\Pipes Catalog\OHDOT Structures\Junction Structures with Frames\Manhole No. 5 (pipe to 42in) (MH-1.3).xml ERROR: Part Validation Failed | Junction Structures with Frames\Manhole No. 5 (pipe to 42in) (MH-1.3).xml